- 300 - 600W Average Power
- Up to 10kW Peak Power and 100J Pulses
- 500 Hz Repetition Rate
- 300 micron Core Fiber Delivery
- Four Energy Share or Time Share
- Excellent Pulse to Pulse Power Stability
- Seam Power Fade In / Fade Out Function
The LW300A – 600A industrial laser welders are specifically designed for high speed seam laser welding applications.
They feature high peak power and pulse stability to meet virtually any production laser welding application requirement.
The lasers can be configured with up to four time or energy share outputs: utilize one laser to support up to four workstations processing different parts with different weld schedules!
Specifications :
|
LW300A |
LW400A |
LW500A |
LW600A |
Wavelength |
1064nm |
|||
Average Power |
300W |
400W |
500W |
600W |
Pulse Energy @ 10mS |
50J |
80J |
80J |
100J |
Peak Power |
5.0kW |
8.0kW |
8.0kW |
10.0kW |
Pulse Width Range |
0.25 to 99.9 mS |
|||
Repetition Rate |
500Hz |
|||
Pulse Shaping Feature |
Yes |
|||
Aiming Laser |
Diode |
|||
Number of Outputs |
Up to 4 |
|||
Energy Share Outputs |
One group of up to 4, or two groups of 2 |
|||
Time Share Outputs |
Up to 4 |
|||
Fiber Core Diameter (SI or GI fibers) |
0.3, 0.4, 0.6, 0.8, 1.0mm |
0.4, 0.6, 0.8, 1.0mm |
0.3, 0.4, 0.6, 0.8, 1.0mm |
0.4, 0.6, 0.8, 1.0mm |
Datacom |
8/7 data, 2/1 stop bits, even/odd parity, RS485/422 |
|||
Power Requirements |
220VAC +10%/-15%, 3 Phase, 50/60Hz |
|||
Line Current |
43A |
84A |
||
Cooling Method |
Water-Water |
|||
External Cooling Water Requirements |
4.2 gal./min. (16 liters/min) @86°F (30°C) |
6.6 gal./min. (25 liters/min) @77°F (25°C) |
||
Cooling Water Inlet Diameter |
0.591 inch (15mm) |
0.748 inch (19mm) |
||
Ambient Operating Temperature |
40 - 95°F (5 - 35°C) |
|||
Humidity |
85% non-condensing @ 77°F (25°C) |
|||
Physical Dimensions H x W x D Inches (mm) |
46.1 x 20.9 x 53.1 (1170 x 530 x 1350) |
47.2 x 21.6 x 70.1 (1200 x 550 x 1780) |
||
Weight lbs. (Kg) |
882 (400) |
992 (450) |
1191 (540) |
|
Special Features |
CE certified units available: please consult factory |
|||
BTU/Hr @ 100% Duty Cycle (Minimum Req.) |
40,300 (3.5) |
59,400 (5) |
||
(tons of cooling) |