- 360度地觀察整個焊接過程,包括焊接觸發前與觸發後的數據
- 可測量電流、電壓、壓力、位移與保護氣體流量
- 高分辨率傳感器
- 易於設置的用戶界面
- 可監控任意電阻焊機
- 啟用了TCP/IP通訊
- 集成式數據庫與Minitab 15統計軟件
With an ever-increasing emphasis on accountability, Miyachi Unitek’s new Advanced Data Analysis Monitor (ADAM) is the most advanced resistance welding monitor available from any manufacturer.
It offers more of the information you need for resistance welding process development, production monitoring and data to support your ISO, and GMP and TQM requirements. Not only will it monitor what happens during the weld, but also before it is triggered, giving you a true 360-degree view of your welding process.
Specification :
Measurement Capability |
Single Channel Current, Voltage, and Gas Flow/Auxiliary 0-10 volt input. Two channels each of Force and Displacement. (Displacement, Force, and Cover Gas Flow Sensors are optional.) |
Parameter |
Ranges |
Displayed Resolution |
Current |
2,6, 20,60, 200 kA |
3 significant digits |
Voltage |
0-15 V |
3 significant digits |
Displacement |
12, 25,30mm |
0.0001” or 0.01mm |
Force |
0-10V |
3 significant digits |
Gas flow/Auxiliary 0-10 Volt |
0-10V |
3 significant digits |
Derived Parameters |
Power = VRMS x IRMS |
Resistance = VRMS / IRMS |
|
Measurement Time Maximum |
2 Seconds Maximum (Depends on Sampling Rate) |
Sampling Rates |
125K Samples per Second |
Repetition Rate |
1 per second for 100 milli second measurement period |
Limits |
Numeric Peak and RMS; Min/Max; Graphical Envelope, Weld Time, Counter |
Displayed Resolution |
Approximately 1000 Data Points Per Waveform |
Triggering |
Current, Voltage, Force with Adjustable Threshold or External Signal |
Digital Inputs |
External Trigger, Reset, Tare Displacement, Reset Counter, Inibit Measurement, Start Part Measurement, Initial Thickness Measurement |
Digital Outputs |
Ready to Measure, In Progress, In Limits, Out of Limits, In Warning, Out of Warning, Counter Limit, Force Fire, Thickness Pass, Thickness Fail |
Relay Outputs |
4 User Configurable Relays Rated: 30VDC and up to 1 A |
Weld Counter |
User Programmable Counter Limit |
Power Supply Cutoff |
Weld to Displacement Based on Electrode Position |
Number of Schedules |
Unlimited |
Communications |
RS-232 (output of weld data after each weld only) Ethernet TCP/IP (remote reading of database) |
Memory |
1 TB Hard Disc |
Electrical Requirements |
115V/230V 50/60 Hz |
ADAM Ordering Guide |
|
Basic System |
Includes Data Processing Module, 21.6" (Diagonal) XGA Display, Keyboard, Mouse, Sensor Interface Module |
Included SPC Package |
Integrated Database and Minitab Statistical Software |
Included Accessories |
(Qty 1 each) MB-400k Current Coil, Voltage Pick-up Leads |
Optional Accessories |
Displacement Sensors, Force Sensor, Gas Flow Sensor (Part No. 270-473) |
Displacement Sensor Part Nos. |
(Part No. 270-458 25mm range, 0.2um accuracy), (Part No. 460-235 12mm range, 0.2um accuracy) (Part No. 311-022 30mm range, 1um accuracy), (Part No. 311-017 12mm range, 1um accuracy) |